Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. dent. j ; 31(4): 399-403, July-Aug. 2020. tab
Article in English | LILACS, BBO | ID: biblio-1132316

ABSTRACT

Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson's correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.


Resumo Este estudo observacional transversal com 24 participantes teve como objetivo avaliar as diferenças na força de mordida (FM) e na PM (performance mastigatória) entre usuários de prótese total convencional (PTC) e de overdenture mandibular (OM) e a correlação entre essas variáveis. O teste de FM foi realizado bilateralmente com um dispositivo de força oclusal. Durante o teste de PM, os pacientes foram solicitados a mastigar uma porção padronizada de Optocal por 40 ciclos mastigatórios. O teste de Shapiro Wilk foi empregado para verificar a normalidade dos dados, o teste T de Student para identificar diferenças entre os grupos e os coeficientes de correlação de Pearson para investigar inter-relações entre variáveis. Uma regressão linear múltipla foi realizada pelo método stepwise. Valores de p≤0,05 foram considerados estatisticamente significantes. Diferentemente dos usuários de OM, os usuários de PTC apresentaram uma diferença significativa (34%) na FM entre o lado dominante e o não dominante (p=0,04). Os usuários de OM apresentaram FM significativamente maior (p=0,01) sem apresentar um lado dominante (p=0,38) e obtiveram PM significativamente melhor nos seguintes parâmetros: os valores de PMX50 diminuíram 27,25% (p=0,01), PMB diminuiu em 48,38% (p=0,01), e EM 5.6 diminuiu 53,25% (p=0,02), enquanto EM2.8 aumentou 151,57% (p=0,01). A FM e PMX50 no grupo de usuários da IMO foram negativamente correlacionados (-0,57;p=0,05); esse coeficiente de correlação foi o único parâmetro incluído no modelo de regressão multivariada. Os usuários da OM possuem maior FM e melhor performance mastigatória do que os usuários de PTC, observados principalmente na redução do tamanho das partículas mastigadas. A PM está correlacionada com um maior FM nos usuários da OM através de uma melhor trituração de partículas.


Subject(s)
Humans , Bite Force , Denture, Overlay , Cross-Sectional Studies , Denture, Complete , Mandible
2.
Braz. dent. j ; 29(2): 202-207, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951528

ABSTRACT

Abstract This study evaluated the effect of the accelerated artificial aging (AAA) on feldspar ceramic strength and the reinforcing effect promoted by adhesive cementation with resin luting agent. One hundred twenty feldspar ceramic disks were obtained. Sixty disks were acid-etched, silanized, and coated with an experimental resin luting agent simulating the adhesive luting procedures. Four groups were created (n=30): uncoated ceramic (control group), uncoated ceramic submitted to AAA, ceramic coated with resin luting agent, and coated ceramic submitted to AAA. Biaxial flexural testing with ball-on-ring setup was carried out. Biaxial flexural strength (s bf , MPa), characteristic strength (s 0 , MPa), and Weibull modulus (m) were calculated for axial positions z=0 (ceramic surface) and z=−t2 (luting agent surface). Data of s bf at positions z=0 and z=-t2 were separately submitted to statistical analyses (a=0.05). The uncoated ceramic submitted to AAA had no significant difference in s bf and s 0 compared with the control group. Resin coating of the ceramic increased s bf and s 0 at z=0. The AAA increased the s bf and s 0 for the resin-coated ceramic specimens at z=0 and also the s 0 at axial position z=-t2. The structural reliability at z=0 and z=-t2 was not influenced by the variables tested. In conclusion, resin coating improved the mechanical strength of the feldspar ceramic. The AAA procedure was not effective in aging the uncoated or resin-coated feldspar ceramic specimens.


Resumo Este estudo avaliou o efeito do envelhecimento artificial acelerado (EAA) na resistência da cerâmica feldspática e o reforço promovido pela cimentação adesiva com cimento resinoso. Cento e vinte discos de cerâmica feldspática foram obtidos. Sessenta discos foram condicionados com ácido, silanizados, e recobertos com um cimento resinoso experimental simulando os procedimentos de cimentação adesiva. Quatro grupos foram criados (n=30): cerâmica sem recobrimento (grupo controle), cerâmica sem recobrimento submetida ao EAA, cerâmica recoberta com cimento resinoso, cerâmica recoberta com cimento resinoso submetida ao EAA. O teste de resistência à flexão biaxial foi realizado utilizando o dispositivo pistão-anel. Resistência à flexão biaxial (s fb , MPa), resistência característica (s 0 , MPa), e módulo de Weibull (m) foram calculados para as posições axiais z=0 (superfície da cerâmica) e z=−t2 (superfície do cimento). Os dados de s fb em z=0 e z=−t2 foram submetidos a análises estatísticas separadamente (a=0,05). A cerâmica não recoberta submetida ao EAA não teve diferença significante na s fb e s 0 comparada com o grupo controle. O recobrimento com cimento resinoso da cerâmica aumentou a s fb e s 0 em z=0. O EAA aumentou a s fb e s 0 para os espécimes de cerâmica recobertos com cimento resinoso em z=0 e também a s 0 em z=−t2. A confiabilidade em z=0 e z=−t2 não foi influenciada pelas variáveis testadas. Concluindo, o recobrimento com cimento resinoso melhorou a resistência mecânica da cerâmica feldspática. O procedimento de EAA não foi efetivo em envelhecer os espécimes de cerâmica feldspática recobertos ou não com cimento resinoso.


Subject(s)
Materials Testing , Potassium Compounds/chemistry , Resin Cements/chemistry , Dental Cements/chemistry , Dental Porcelain/chemistry , Aluminum Silicates/chemistry , Dental Bonding , Composite Resins/chemistry , Dental Stress Analysis
SELECTION OF CITATIONS
SEARCH DETAIL